Lexmark X736de Fuser Life Reset Counter Procedure

 

Lexmark X736de Fuser Life Reset Counter Procedure 40X8110, 40X5093

Unlike some models, the fuser life counter needs to be manually reset on these machines.Below you will find the Instructions for the  Lexmark X736de Fuser Life Counter Reset Procedure. Also, you will find a link to the replacement instructions and links to order in a replacement fuser if you have don’t so, already.

Lexmark X736de Fuser Life Counter Reset

Rated at 120,000 these fusers tend to hold pretty well. On newer machines this error tends to mean you need to replace the fuser or I ain’t going to print. Therefore, you probably should pay attention and when the machine tells the life is near the end and get your replacement on order.

Fuser Warning Messages
80 Fuser Near Life Warning
80 Fuser Life Warning
80 Replace Fuser
120.00–120.21 Fuser Error


Lexmark X736de – 40X8110, 40X5093 Fuser

Lexmark X736de Fuser Replacement and Reset

Lexmark X736de Fuser Life Counter Reset

Installation note: If you install a new fuser, be sure to reset the fuser counter in the Configuration Menu. To reset the counter:

Fuser Reset Instructions for the Multifunction X700 Series Machines

1. Turn off the multifunction printer, press and hold buttons 2 and 6, turn on the MFP, and release the buttons when the progress bar displays.
2. Touch Reset Fuser Cnt from the Configuration Menu.
3. Touch Yes or No.
4. Select Exit Config Menu.

Fuser Reset Instructions for the Printer C740 Series Machines With Control Panel

1. Enter the Configuration Menu. (Turn off the printer, press and hold buttons 2 and 6, turn on the printer, and release the buttons when the progress bar displays.)
2. Press “OK” for the Reset value.
Resetting Fuser Count Value appears.
3. Select Motor Calibration from the CONFIG MENU.
Calibrating displays, and the printer prints several blank pages and then returns to the CONFIG MENU.
4. Select Exit Config Menu.

Fuser Reset Instructions for the Printer C730 Series Machines

Installation note: If you install a new fuser, be sure to reset the fuser counter in the Configuration Menu, and run the Motor Calibration. To reset the counter and run the calibration:
1. Enter the Configuration Menu. (Turn off the printer, press and hold Select (√ )and  ⇒, turn on the printer, and release the buttons when the clock graphic displays.)
2. Press Select (√ ) for the Reset value.
Resetting Fuser Count Value appears.
3. Select Motor Calibration from the CONFIG MENU.
Calibrating displays, and the printer prints several blank pages and then returns to the CONFIG MENU.
4. Select Exit Config Menu.

If your reading this message and just resetting the life counter without replacing the fuser. Do yourself and machine a favor and get the replacement on order. Nothing is worse than having your machine go down and knowing you could have prevented it by spending a little money on maintaining it. Click on the link below to find the replacement instructions.

Lexmark X736de Fuser Replacement

We will be happy to hear your thoughts

Leave a reply

Shopping cart