Kyocera KM-C2525E, C3225E, C3232E, C4035E C7240 Call for Service

 

Kyocera KM-C2525E, C3225E, C3232E, C4035E C7240 Call for Service Instructions

Below you will find the service manual information for the Kyocera KM-C2525E, C3225E, C3232E, C4035E C7240 Call for Service along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Kyocera KM-C2525E, C3225E, C3232E, C4035E C7240 Call for Service

Service Manual Instructions for the Kyocera KM-C2525E, C3225E, C3232E, C4035E C7240 Call for Service

Kyocera KM-C2525E, KM-C3225E, KM-C3232E, KM-C4035E C7240 Call for Service

Description :
Broken internal thermistor 3 wire An abnormal value is detected in the input data to inner temperature sensor 3.

Causes :
1. Poor contact in the connector termi- nals.
2. Defective engine PWB.
3.
4.
5.
6.

Solutions :
1. Check the connection of connector YC8 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary.
2. Replace the engine PWB and check for cor- rect operation
3.
4.
5.
5.

Remember, not every error is exactly the same. What fixes the Kyocera KM-C2525E, C3225E, C3232E, C4035E C7240 Call for Service one time might not solve it the next time. While the information above comes from the service manual and generally should get your machine up and running, sometimes other factors might be in play.

If you are reading this article and have experience with this error and would like to contribute please leave a comment below. Or, if you have read this article and have additional questions then ask. If I have experience with the issue then I will respond.

We will be happy to hear your thoughts

Leave a reply