Kyocera FS2020D, FS3920DN, FS4020DN Service Call 6030 Instructions
Below you will find the service manual information for the Kyocera FS2020D, FS3920DN, FS4020DN Service Call 6030 along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it.Â
Service Manual Instructions for the Kyocera FS2020D, FS3920DN, FS4020DN Service Call 6030
6030 Broken fuser thermistor 2 wire
Description :
Input from fuser thermistor 2 is less than 1 (A/D value) for more than 1 s.
Causes :
Poor contact in the fuser thermistor 2 connector terminals.
Broken fuser thermistor 2 wire.
Fuser thermistor 2 installed incorrectly.
Thermal cutout triggered.
Fuser heater lamp installed incorrectly.
Broken fuser heater lamp wire.
Solutions :
Reinsert the connector.
Measure the resistance.
If it is ???, replace the fuser thermistor 2.
Check and reinstall if necessary.
Check for continuity.
If none, replace the thermal cutout.
Check and reinstall if necessary.
Check for continuity.
If none, replace the fuser heater lamp.
Kyocera FS2020D FS3920DN FS4020DN Fuser Replacement
Kyocera Fuser Kit FK-350
Features
- 302J193050 302J193051 302J193052 30
Remember, not every error is exactly the same. What fixes the Kyocera FS2020D, FS3920DN, FS4020DN Service Call 6030 one time might not solve it the next time. While the information above comes from the service manual and generally should get your machine up and running, sometimes other factors might be in play.
If you are reading this article and have experience with this error and would like to contribute please leave a comment below. Or, if you have read this article and have additional questions then ask. If I have experience with the issue then I will respond.
Trocando Fusor FK-350
Retirando e instalando Fusor Kyocera FS-4020/3040/3540.