Kyocera FS2020D, FS3920DN, FS4020DN Service Call 6020 Instructions
Below you will find the service manual information for the Kyocera FS2020D, FS3920DN, FS4020DN Service Call 6020 along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it.Â
Service Manual Instructions for the Kyocera FS2020D, FS3920DN, FS4020DN Service Call 6020
6020 Abnormally high fuser thermistor 2 temperature
Description :
The temperature of the fuser thermistor 2 detects 240?C/464?F or more continuously for 3 s.
Causes :
Shorted fuser thermistor 2.
Defective engine PWB.
Solutions :
Measure the resistance.
If it is 0 ?, replace the fuser thermistor 2.
Replace the engine PWB
99% of the time fuser related errors are caused by the fusing unit. Therefore, if you don’t fell like testing the OHMS on the thermistor then your best bet it to just order in a new fuser and replace it. Below you will find a link to the fuser replacement instructions and below that, a link to order in a replacement fuser.
Kyocera FS2020D FS3920DN FS4020DN Fuser Replacement
Kyocera Fuser Kit FK-350
Features
- 302J193050 302J193051 302J193052 30
Remember, not every error is exactly the same. What fixes the Kyocera FS2020D, FS3920DN, FS4020DN Service Call 6020 one time might not solve it the next time. While the information above comes from the service manual and generally should get your machine up and running, sometimes other factors might be in play.
If you are reading this article and have experience with this error and would like to contribute please leave a comment below. Or, if you have read this article and have additional questions then ask. If I have experience with the issue then I will respond.