Below you will find the service manual information for the Canon imageRUNNER 1750, 1740, 1730 Error Code E820 0001 along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Canon imageRUNNER 1750, 1740, 1730 Error Code E820 0001

Service Manual Instructions for the Canon imageRUNNER 1750, 1740, 1730 Error Code E820 0001

E820 0001 Error in rotation of the Developing Cooling Fan (Front) (FM7)

Description :
Description A lock signal could not be detected for 5 seconds while the Developing Cooling Fan (Front) (FM7) was being driven. *The same status was detected again after executing an error retry.

Causes :
Error in rotation of the Developing Cooling Fan (Front) (FM7)

Solutions :
Remedy

1. Disconnect and then connect the connector (J209) on the DC Controller PCB (PCB1) to check the connection.

2. Replace the Developing Cooling Fan (Front) (FM7).

3. Replace the DC Controller PCB (PCB1).

Remember, not every error is exactly the same. What fixes the Canon imageRUNNER 1750, 1740, 1730 Error Code E820 0001 one time might not solve it the next time. While the information above comes from the service manual and generally should get your machine up and running, sometimes other factors might be in play.