Kyocera FS3900DN, FS4000DN Call Service 5100 Error Code Instructions
Below you will find the service manual information for the Kyocera FS3900DN, FS4000DN Call Service 5100 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it.Â
Service Manual Instructions for the Kyocera FS3900DN, FS4000DN Call Service 5100 Error Code
5100 Short-circuited main charger output
Description :
5100 Short-circuited main charger output
Five pages have been printed with the main charger output short-circuited.
Causes :
Drum unit installed incorrectly.
Engine PWB installed incorrectly.
Defective engine PWB.
Solutions :
Verify harness is not pinched in the drum unit.
Verify harness is not pinched in the engine PWB.
Replace the engine PWB
Remember, not every error is exactly the same. What fixes the Kyocera FS3900DN, FS4000DN Call Service 5100 Error Code one time might not solve it the next time. While the information above comes from the service manual and generally should get your machine up and running, sometimes other factors might be in play.
If you are reading this article and have experience with this error and would like to contribute please leave a comment below. Or, if you have read this article and have additional questions then ask. If I have experience with the issue then I will respond.