Below you will find the service manual information for the Kyocera FS1370DN 2000 Error Code Troubleshooting Information along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 
Kyocera FS1370DN 2000 Error Code

Service Manual Instructions for the Kyocera FS1370DN 2000 Error Code Troubleshooting Information

2000 Main motor error
Description :
The main motor ready input is not given for 2 s during the main motor is ON.
Causes :
Defective harness between main motor (CN1) and control PWB (YC305), or improper connector insertion. Defective main motor.

Defective control PWB.

Defective drive transmission system of the main motor.
Solutions :
Check if the rollers and gears rotate smoothly.

Reinsert the connector.

Also check for continuity within the connector harness.

If none, remedy or replace the harness.

If not, grease the bushings and gears.

Check for broken gears and replace if any.

Replace the main motor

Replace the control PWB

Remember, not every error is exactly the same. What fixes the Kyocera FS1370DN 2000 Error Code Troubleshooting Information one time might not solve it the next time. While the information above comes from the service manual and generally should get your machine up and running, sometimes other factors might be in play.