Ricoh, Lanier, Savin SP C240, SP C242 SC541 Error Code

 

Ricoh, Lanier, Savin SP C240, SP C242 SC541 Error Code Troubleshooting

The Ricoh, Lanier, Savin SP C240, SP C242 SC541 Error Code is related to a low temperature reading. While this can be a serious error, sometimes it can be an easy fix. Below you will find information from the service manual along with some additional troubleshooting tips. Also, you will find links to the error code reset, links to the fuser replacement instructions, and links to purchase a new fuser.

Ricoh, Lanier, Savin SP C240 , SP C242 SC541 Error Code

M096-4017 (M0964017) Fuser (Fixing) Unit – 120 Volt Ricoh Aficio SPC240SF SPC242DN SPC242SF SPC250DN SPC252DN

Service Manual Troubleshooting for the Ricoh, Lanier, Savin SP C240, SP C242 SC541 Error Code

Anytime you see this error or any fuser related error, the error has to be reset through service mode anytime it appears. Therefore, while troubleshooting, you might need to enter into service mode multiple times to reset the code to move onto the next step. Even if you replace the fuser, the error code will have to be reset if it hasn’t been done already. Below is the link to the Fuser SC reset instructions.
Ricoh, Lanier, Savin SP C240, SP C242 Fuser SC Reset
Description :
The thermistor output is less than 0°C for 7 seconds.
Possible Causes
Disconnected thermistor
Defective harness connection
Possible Solutions :
1. Check the harness connection of the thermistor.
2. Replace the fusing unit.

Additional Information on the Ricoh, Lanier, Savin SP C240, SP C242 SC541 Error Code

Step 1 : Try the reset. Most times simply doing  the reset will fix your problem.

Step 2 : Check the power source. It is strongly recommended not to plug the unit into a power strip or battery backup. For testing purposes, Plug the unit straight into a wall outlet.

Step 3 : If the machine has just been brought into from an extremely cold temperature. Let the machine sit, 1 to 2 hours to adjust to room temperature.

Step 4 : Remove the fuser and check the connectors, Remove the thermistor and clean, make sure it is properly seated. Typically, the thermistor rides just on the surface of the hot roller.

Step : Replace the fuser.

Step : Ricoh, Lanier, Savin SP C240 , SP C242 Fuser Replacement

We will be happy to hear your thoughts

Leave a reply