922 Fuser Error – Lexmark T 630, 632, and 634 Optra Printer Series

 

Repair Advice for the Lexmark Optra T Series 630, 632, and 634 922 Fuser Error

The 922 Fuser Error happens when the machine fails to reach the standby temperature in the allowed amount of time. You might see the 920 or 921 error then when you turn the machine back on get the 922 Fuser Error meaning that you have a more serious error. Sometimes turning the machine off then back on will resolve the issue, other times you will have to dig a little deeper and replace some parts. The good news about these fuser errors is that 99% of the time they are limited to the fusing assembly. After replacing the fusing the problem is fixed and your back in business. Below is several simple troubleshooting tips and a few links to further diagnose the problem or instructions on how to remove and replace the fusing assembly if needed.

Lexmark Optra T630, T632, T634 922 Fuser Error

Lexmark Optra T630, T632 Fusing Assembly – 56P1333

Troubleshooting Tips

1. Turn the machine off then back on.

2. Check the power source. No power strips and battery back ups. Make sure the machine is plugged straight into a wall outlet. Trya a different wall outlet.

3. Remove the fusing assembly and clean the thermistor surface. Because the thermistor sensor rides on the surface of the hot roller debris like to built up on it. Make sure the thermistor is riding on top of the hot roller. If the thermistor is just a little off the roller and you will get a false low temperature error.

4. Perform the cold fuser check list
Cold Fuser Check – Lexmark T630, T632, T634 Printer Repair

5. Replace the fusing assembly.
Lexmark Optra T Fuser Replacement T630, T632, and T634 Printers

 