Kyocera KM-3060 Fuser Error Reset Procedure – 302K593060

 

Kyocera KM-3060 Fuser Error Reset Procedure

Below you will find the Kyocera KM-3060 Fuser Error Reset Procedure. Some machines have this feature others don’t. They tend to be more common on these larger models. The purpose is to prevent overheating in the unit that can lead to more serious issues and additional damage to the machine. Most manufactures recommend waiting at least 15 minutes before resetting the fuser error to allow the unit to cool down. I usually spend this time taking the fuser out and inspecting the thermistors, thermostats, lamp contact points, and the overall condition of the unit.

out of stock
as of March 26, 2024 4:20 am
Amazon.com
Last updated on March 26, 2024 4:20 am


I tend to treat these errors like the check engine light on your car. If it comes on once or twice a year then it’s probably not that big of a deal, you probably should at least have it looked at. However, if it comes on once or twice every few weeks or months then we probably have a more serious problem.

Now, if you perform the reset and the error comes back then look under that category of the machine for additional information on that particular error or click on the link at the bottom of the article for the fuser removal and replacement instructions.

Kyocera KM-3060 Fuser Error Reset Procedure

Kyocera KM-3060 Fuser Error Codes that Require a Kyocera KM-3060 Fuser Error Reset Procedure

C6000 Fuser heater break
C6020 Abnormally high fuser thermistor temperature
C6050 Abnormally low fuser thermistor temperature
C6120 Abnormally high fuser thermistor temperature
C6150 Abnormally low fuser thermistor temperature
C6400 Zero-cross signal error
C6420 Fuser unit fuse cut problem

Executing a maintenance item
Press the status key.
Enter “10871087” using the numeric keys.
Maintenance mode is entered.
Enter the maintenance item number using the cursor up/down keys or numeric keys. U163
The maintenance item is selected.
1. Press the start key.
2. Press [EXECUTE] on the touch panel.
3. Press the start key. The fuser problem data is initialized.
4. Turn the main power switch off and on.

Service Manual Information on the Kyocera KM-3060 Fuser Error Reset Procedure

U163 Resetting the fuser problem data
Description
Resets the detection of a service call code indicating a problem in the fuser section.
Purpose
To prevent accidents due to an abnormally high fuser temperature.
Method
1. Press the start key.
2. Press [EXECUTE] on the touch panel.
3. Press the start key. The fuser problem data is initialized.
4. Turn the main power switch off and on.

Below is the link to the replacement instructions so you can remove the fuser and inspect it or if the error will not go away, replace it.