Lexmark X748dte, X748de Fuser Replacement and Reset

 

Lexmark X748dte, X748de Fuser Replacement and Reset 40X8110, 40X5093

Below you will find the illustrated Lexmark X748dte, X748de Fuser Replacement Instructions along with the Reset Instructions. Rated at 120,000 these fusers tend to hold pretty well. Like any other color machine, the life of the fuser is rated a lot less than the monochrome models therefore, replacement happens more often.

Fuser Warning Messages
80 Fuser Near Life Warning
80 Fuser Life Warning
80 Replace Fuser
120.00–120.21 Fuser Error

$116.25
$279.34
in stock
39 new from $116.25
as of March 18, 2024 2:26 am
Amazon.com
Last updated on March 18, 2024 2:26 am

Lexmark X748dte, X748de Fuser assembly removal

1. Turn off the printer.
2. Open the top access door.
3. Open the front access door.
4. Rotate the fuser thumbscrews counterclockwise until loosened.
5. Grasp the handles, slide the fuser out from the printer.

Lexmark X748dte, X748de Fuser Replacement and Reset

Installation note: If you install a new fuser, be sure to reset the fuser counter in the Configuration Menu. To reset the counter:

Fuser Reset Instructions for the Multifunction X700 Series Machines

1. Turn off the multifunction printer, press and hold buttons 2 and 6, turn on the MFP, and release the buttons
when the progress bar displays.
2. Touch Reset Fuser Cnt from the Configuration Menu.
3. Touch Yes or No.
4. Select Exit Config Menu.

Fuser Reset Instructions for the Printer C740 Series Machines With Control Panel

1. Enter the Configuration Menu. (Turn off the printer, press and hold buttons 2 and 6, turn on the printer, and
release the buttons when the progress bar displays.)
2. Press “OK” for the Reset value.
Resetting Fuser Count Value appears.
3. Select Motor Calibration from the CONFIG MENU.
Calibrating displays, and the printer prints several blank pages and then returns to the CONFIG MENU.
4. Select Exit Config Menu.

Fuser Reset Instructions for the Printer C730 Series Machines without Control Panel

Installation note: If you install a new fuser, be sure to reset the fuser counter in the Configuration Menu, and
run the Motor Calibration. To reset the counter and run the calibration:
1. Enter the Configuration Menu. (Turn off the printer, press and hold Select (√ )and  ⇒, turn on the printer,
and release the buttons when the clock graphic displays.)
2. Press Select (√ ) for the Reset value.
Resetting Fuser Count Value appears.
3. Select Motor Calibration from the CONFIG MENU.
Calibrating displays, and the printer prints several blank pages and then returns to the CONFIG MENU.
4. Select Exit Config Menu.