Below you will find the service manual information for the Kyocera FS3040MFP and FS3140MFP C3200 Error Code along with additional details to explain what can cause the problem and followed by solutions that might help you fix it. If I have additional information from past experiences I will try to add it. 

Kyocera FS3040MFP and FS3140MFP C3200 Error Code

Service Manual Instructions for the Kyocera FS3040MFP and FS3140MFP C3200 Error Code

3200 Exposure lamp error
Description :
When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s.
Causes :
Defective connector cable or poor contact in the connector.
Defective exposure lamp or LED drive PWB.
Defective CCD PWB.
Defective main PWB.

Solutions :
Reinsert the connector. Also check for continuity within the connector cable. If one, remedy or replace the cable.
LED PWB (YC1) and LED drive PWB (YC2) LED drive PWB (YC1) and CCD PWB (YC3) CCD PWB (YC2) and main PWB (YC8) Replace the scanner unit
Replace the main PWB and check for correct operation

Remember, not every error is exactly the same. What fixes the Kyocera FS3040MFP and FS3140MFP C3200 Error Code one time might not solve it the next time. While the information above comes from the service manual and generally should get your machine up and running, sometimes other factors might be in play.