Ricoh, Lanier, Savin SP C250 , SP C252 SC542 Error Code Service

 

Ricoh, Lanier, Savin SP C250 , SP C252 SC542 Error Code Service Explained

The Ricoh, Lanier, Savin SP C250 , SP C252 SC542 Error Code is related to a low temperature reading in the fusing unit while trying to get up to ready temperature. This error can be easily resolved with a few quick steps or may need to have the fusing unit replaced. Below you will find troubleshooting tips along with links to order in a new fuser and links to the fuser replacement and code reset instructions.

Ricoh, Lanier, Savin SP C250 , SP C252 SC542 Error Code Service
M096-4017 (M0964017) Fuser (Fixing) Unit – 120 Volt Ricoh Aficio SPC240SF SPC242DN SPC242SF SPC250DN SPC252DN

Service Manual Advice for the Ricoh, Lanier, Savin SP C250 , SP C252 SC542 Error Code Service

These errors can only be reset through putting the machine into service mode. Each time you go through a troubleshooting step and see the error again, or any other fuser related service error, the code will need to be reset. So the first step is to always reset the error code. Therefore, before going any further you should reset the error code and see what happens. Click on the link below to be taken to the reset instructions.

Ricoh, Lanier, Savin SP C250 , SP C252 Fuser SC Reset Procedure

Print Ready Temperature Error
Possible Causes :
1. The heating roller temperature increase during a set time is not correct.
2. The fusing temperature does not reach the print ready temperature within a set time after the fusing lamp has turned on.
3. Defective thermistor
4. Incorrect power supply input at the main power socket
5. Defective fusing lamp
Posible Solutions :
1. Check the voltage of the wall outlet.
2. Replace the fusing unit
3. Replace the fusing lamp.

Additional Advice for the Ricoh, Lanier, Savin SP C250 , SP C252 SC542 Error Code Service

  1. Reset the error code. Sometimes these units just fail to get up to temperature in time. I’d say 75% of the time this step will solve your problem. My theory is that if it happens once or twice a year then its ok. If it happens a few times in a few weeks or months then you probably have a more serious issue going on that needs further troubleshooting.
  2. Check the power supply. For testing purposes, plug the unit straight into a wall outlet and make sure no other large power consuming devices are on the same circuit. No power strips and especially no battery backups.
  3. Make sure the room is at a normal temperature. If you have just moved the machine then make sure it sits for a few hours to adjust to room temperature.
  4. Remove the fusing unit and check the thermistors, clean if needed. On most machines the thermistor rides on the surface of the hot roller, so make sure that when it is installed it slightly touches the surface. Check the fuser lamp and thermal fuses for continuity.
  5. Check the connectors.
  6. Replace the fuser.