Canon imageCLASS Series D1320, D1350, D1370, D1380 Fuser Removal
Below you will find the illustrated instructions for the Canon imageCLASS Series D1320, D1350, D1370, D1380 Fuser Removal. While these fusers tend to hold up rather well given the size of the machine. They eventually will need to be replaced. Most the ones I’ve seen wear out around 150,000 pages. The sides of the fuser heating sleeve starts to wear down and you get streaks, ghosting, smudging, and paper jamming around the edges of the paper. The best way to tell is to open up the back door and with a flashlight, check out the grey heating element. If you see discolorization on it, then that part  is getting worn down and will most likely be the source of your problem or will soon be.
Note : These Canon models use the same fuser as the HP P2035 / P2055. So don’t be surprised when the links to order in a replacement fuser show it has a HP fuser.
Fuser Works in :
Canon imageCLASS D1120
Canon imageCLASS D1150
Canon imageCLASS D1170
Canon imageCLASS D1180
Canon imageCLASS D1320
Canon imageCLASS D1350
Canon imageCLASS LBP6300dn
Canon imageCLASS LBP6650dn
Canon imageCLASS LBP6670dn
Canon imageCLASS MF5850dn
Canon imageCLASS MF5880dn
Canon imageCLASS MF5950dw
Canon imageCLASS MF5960dn
Canon imageCLASS MF6160dw
Canon imageCLASS MF6180dw
Canon imageRUNNER LBP3470
Canon imageRUNNER LBP3480
Canon LASER CLASS 650i
HP LaserJet P2035
HP LaserJet P2035n
HP LaserJet P2055d
HP LaserJet P2055dn
HP LaserJet P2055x
Fuser 110v RM1-6405-000, FM4-3436-000 – Canon imageCLASS D1320, D1350, D1370, D1380
1) Remove the cassette.
2) Press the Open button, and open the Front Cover.
3) Open the ADF Unit + Reader Unit.
4) Place the host machine while shifting the left side of it approx. 10cm from the working
table to release the claw at the lower side of the Left Cover Unit.
CAUTION:
Be careful not to drop the host machine when shifting it.
5) Release the claw
6) Release the claw while pulling the Left Cover Unit in the direction of the arrow.
7) While opening the Left Cover Unit in the direction of the arrow, release the 2 Claws
at lower side.
8) Remove the Left Cover Unit in the direction of the arrow.
1) Removing the Left Cover Unit.
â– â– Procedure
1) Release the claw, and remove the Arm Cover.
2) Release the Connection of Arm and turn it toward the rear.
CAUTION:
When opening/closing the ADF+Reader Unit after releasing the arm, be sure perform the work while supporting the ADF+Reader Unit. Be careful not to get your hand caught.
3) Open the ADF Unit + Reader Unit, and release the 2 Claws.
4) While lifting left side of the host machine, remove the Left Rear Cover.
1) Remove the cassette.
2) Press the Open button, and open the Front Cover.
3) Open the ADF Unit + Reader Unit.
4) Release the claw, and remove the Arm Cover.
5) Release the Connection of Arm and turn it toward the rear.
CAUTION:
When opening/closing the ADF+Reader Unit after releasing the arm, be sure perform the work while supporting the ADF+Reader Unit. Be careful not to get your hand caught
6) Place the host machine while shifting the left side of it approx. 10cm from the working
table to release the claw at the lower side of the Right Cover Unit.
CAUTION:
Be careful not to drop the host machine when shifting it.
7) Open the ADF Unit + Reader Unit, and release the 2 Claws while pulling the Right
Cover Unit in the direction of the arrow.
8) Close the ADF Unit + Reader Unit, and release the 2 Claws at lower side while pulling the Right Cover Unit in the direction of the arrow.
9) Open the ADF Unit + Reader Unit, and release the claw while pulling the Right Cover Unit in the direction of the arrow
10) Remove the Right Cover Unit.
1) Push the Grip Downward and Open the Duplex Feed Unit.
2) Remove the Rear Cover Unit.
3) Remove the Duplex Feed Unit from the Rear Cover Unit.
• 2 Bosses
Procedure at installation:
1) Fit the 2 Upper Claw of the Rear Cover Unit With the Upper Cover Unit.
2) Open the Rear Upper Cover and While Pushing the Duplex Reverse Sensor Flag Downward, Install the Rear Cover Unit.
3) Check That the Sensor Flag Through the Hole of the Back of the Duplex Unit
Cover.
Canon imageCLASS Series D1320, D1350, D1370, D1380 Fuser Removal Procedure
CAUTION:
When Removing the Fixing Assembly, Perform the Operation After the Fixing Assembly
is Surely Cooled.
The Fixing Assembly Just After Printing May Cause Burn Injury.
1) Close the Front Cover and Move the Gear In the Position Where It Can Be Removed.
2) Remove the 3 Gears.
CAUTION:
Points to Note at Installation
• Fit the Protrusion of the Gear With the Cut-off of the Gear and Install it.
• Fit the Cut-off of the Gear With the Teeth of the Fan Gear and Install it.
3) Remove the Duplex Feed Sensor Unit.
4) Remove the Harness from the Wire saddle.
5) Remove the Feed Guide.
6) Remove the Fixing Assembly.
CAUTION:
Do Not Disassemble the Fixing Assembly at a Field.
It May Cause a Malfunction.