Canon D1120, D1150, D1170, D1180 E002 0 Error Code

 

Canon D1120, D1150, D1170, D1180 E002 0 Error Code

The Canon D1120, D1150, D1170, D1180 E002 0 Error Code is related to a low temperature reading in the fusing assembly. Below you will see what the service manual has to say along with some other advice to help work through the problem. Also, you will find links to replace the fusing assembly and links to purchase a replacement fuser if needed.

Canon D1120, D1150, D1170, D1180 E002 0 Error Code

 

Canon imageCLASS D1120, D1150, D1170, D1180 Fuser

Service Manual Tips for the Canon D1120, D1150, D1170, D1180 E002 0 Low temperature during temperature control.

The target temperature is not reached during temperature control.
– Check the connector of the fixing film unit.
– Replace the fixing film unit. Canon D1120, D1150, D1170, D1180 Fuser Removal
– Replace the Engine controller PCB.

Additional Tips for the Canon D1120, D1150, D1170, D1180 E002 0 Error Code

  1. Turn the machine off then back on. Sometimes the machine just gets a bad reading or for some unseen reason it just doesn’t get up to temperature in time. Most times this is due to a sudden power outage, low voltage, or other environmental situation.
  2. Check the power source. No power strip or battery back up. For testing purposes, plug the machine straight into a wall outlet.
  3. Remove the fuser and check the connectors.
  4. If the machine has just been moved from an extremely cold environment then let the machine set for 2 hours then try again.
  5. Replace the fuser. Canon D1120, D1150, D1170, D1180 Fuser Removal

Fuser 110v - New - P2035 / 2055 Series

Price: $118.23

1 used & new available from $118.23