Canon imageRUNNER 1750,1740,1730 E002-0000 Error Code

 

Canon imageRUNNER 1750,1740,1730 E002-0000 Error Code

The Canon imageRUNNER 1750,1740,1730 E002-0000 Error Code happens when the main thermistor reports the fuser didn’t get up to the temperatures it was expecting in the specified amount of time allowed. Several things can cause this issue and sometimes it can be easily resolved. Below you will find what the service manual has to say on the topic and few other tips that might come in useful. Also, you will find links to the error code reset instructions, links to replace the fuser, and links to order in a replacement fuser if needed.

Canon imageRUNNER 1750,1740,1730 E002-0000 Error Code

Service Manual Tips for the Canon imageRUNNER 1750,1740,1730 E002-0000 Error Code

Note : Anytime the machine reports an Error related to the fuser, it will have to be reset in service mode. Therefore, don’t be surprised to be resetting the error multiple times when troubleshooting if the problem goes beyond Step 1.

Problem : Error in temperature rising of Fixing Assembly
Description :
1. The Main Thermistor detected a temperature lower than 115 deg C for 400 msec or longer on end 6.0 seconds after the Main Thermistor detected 100 deg C.
2. The Main Thermistor detected a temperature lower than 150 deg C for 400 msec or longer on end 6.0 seconds after the Main Thermistor detected 140 deg C.
RemedyPossible Solutions :
1. Go through the following to clear the error: CLEAR > ENGIN > ERRCLR in Service Mode; then, turn OFF and then ON the power.
Canon imageRUNNER 1750,1740,1730 Service Mode / Fuser Code Reset
2. Check the connector connection. (J206 on the DC Controller PCB, J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
Canon imageRUNNER 1750,1740,1730 Fuser Replacement
4. Replace the DC Controller PCB.

Additional Information on the Canon imageRUNNER 1750,1740,1730 E002-0000 Error Code

  1. Turn the machine off then back on. It might not hurt to turn the machine off, unplug, wait 20 to 30 seconds then plug back in and reset the error. These errors can be a result of a sudden power outage like a lightening strike near by, windy days, or areas that are prone to power issues.
  2. Canon imageRUNNER 1750,1740,1730 Service Mode / Fuser Code Reset
  3. Check the power source. No power strips or battery back ups. Power strips plugged into power strips. Old buildings. Large device like heaters, other laser printers, or coffee makers can all cause power issues.
  4. Remove fuser and check connectors.
  5. I’ve even seen blowing out machines with canned air cause low temperature reading in the fuser.
  6. Canon imageRUNNER 1730 Fuser Unit Removal and Replacement Procedure

    How to change the Fixing Assembly for the imageRUNNER ADVANCE 400IF.

    How to change the Fixing Assembly for the imageRUNNER ADVANCE 400IF. Canon imageRUNNER ADVANCE 400IF Fixing Assembly, compatible with: For ...